Maintenance Object Repair Procedures 
Page 10-1554
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Loss of Signal Alarm Inquiry Test (#138)
This test verifies the synchronization status and continuity of the DS1 link. The 
Loss of Signal alarm indicates that the UDS1 Interface circuit pack is unable to 
derive the synchronization clock from the DS1 facility. When the UDS1 Interface 
circuit pack detects a Loss of Signal alarm, it stops providing the synchronization 
clock for the system if it is administered as a timing source and transmits a 
Yellow alarm to the remote DS1 endpoint.
When the Loss of Signal alarm is confirmed, the maintenance software places all 
trunks or ports of the UDS1 Interface circuit pack into the out-of-service state. 
The inquiry test will run every 10 minutes until the loss of signal has been 
restored.
The UDS1 Interface circuit pack raises a Loss of Signal alarm after the signal has 
been lost for about 3 seconds. It will not retire the alarm until the signal has 
returned for about 10 seconds.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-459.
TEST #135 Internal Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page