Maintenance Commands and Trouble-Clearing Aids 
Page 8-37
busyout spe-standby 
8
Error Messages
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
If this command is issued while an 
upgrade software
 command is active the 
following message will be displayed:
 Standby SPE upgrade in progress, command denied
Output
For the following output example, assume that the standby SPE is located in 
carrier "B." The command that was entered is "busyout spe-standby."
Feature Interactions
When a busyout of the standby SPE is performed, the fault severity level of the 
standby SPE is set to the highest possible value and memory shadowing is 
turned off. This is done to lessen the probability that the system will switch to the 
standby SPE. However, in some cases a "spontaneous" (hard) interchange of the 
SPEs may still occur.
Port
The port address displays the cabinet and carrier location of the 
standby SPE. The standby SPE port address is always 01A or 
01B.
Maintenance Name
"STBY-SPE" for the standby SPE maintenance object.
Alt. Name
Always blank for this command.
Result
The result of the busyout -"PASS," "ABORT," "FAIL,"
Error Code
A system-generated number that tells why the busyout failed or 
aborted. A detailed list of the codes can be in the 
"Busyout/Release Error Codes" section of this chapter.
 
 busyout spe-standby                            SPE A
                           COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01B     STBY-SPE                       PASS
 Command successfully completed