Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1660
WAE-PORT (Wideband Access Endpoint Port) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test
, for example, you may also clear errors generated from other tests 
in the testing sequence.
NPE Crosstalk Test (#6)
One or more Network Processing Elements (NPEs) reside on each circuit pack 
with a TDM Bus interface. (The TN464C UDS1 circuit pack has one 
SCOTCH-NPE chip instead of several NPE chips). The NPE controls port 
connectivity and gain, and it provides conferencing functions on a per-port 
basis. The NPE Crosstalk Test verifies that this port’s NPE channel talks on the 
selected time slot and that it never crosses over to time slots reserved for other 
connections. If the NPE is not working correctly, one-way and noisy connections 
may be observed. This test is usually only part of a port’s Long Test Sequence, 
and it takes between 20 and 30 seconds to complete.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Port Audit and Update Test (#36)
X
X
ND
Table 10-488.
TEST #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page