Maintenance Object Repair Procedures 
Page 10-1670
XXX-BD (Common Port Circuit Pack) 
10
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
G3iV1-1.286 or G3iV2-386 only
Common Port Circuit Pack Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test board PCSS sh r 1
1(a)
0
Circuit pack 
removed or SAKI 
Sanity Test (#53)
MINOR
ON
18(b)
0
busyout board 
PCSS
WARNING
OFF
release board PCSS
23(c)
0
None
WARNING
OFF
36 (d)
4368
none
125 (e)
None
MINOR
ON
217
2
 (f)
0
None
WARNING
ON
257
65535
Control Channel 
Test (#52)
MINOR
ON
test board PCSS sh r 20
257 (g)
Any
None
267 (f)
0
None
WARNING
ON
513 (h)
Any
None
MINOR
ON
test board PCSS sh
769 (i)
4358
None
1025 (j)
4363
NPE Audit Test 
(#50)
test board PCSS l r 20
1281  (k)
Ringing Application 
Test (#51)
MINOR
ON
test board PCSS r 2
1538 (l)
Any
None
WARNING/ 
MINOR
ON
1793 (m)
Neon Test (#220)
MINOR
ON
test board PCSS r 2
3840 (n)
Any
None
3999 (o)
Any
None