Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-48
cancel hardware-group 
8
Output
For the following output example, assume that the command that was entered is 
"busyout trunk 78/1."
Feature Interactions
None.
cancel hardware-group
This command allows a user to cancel an active "test hardware-group" command 
executing in the background or foreground mode.
Synopsis
cancel hardware-group
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being busied out.
Maintenance Name
The type of maintenance object that is being busied out.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.
Result
The result of the busyout - "PASS", "ABORT", "FAIL".
Error Code
A system-generated number that tells why the busyout failed or 
aborted. A detailed list of the codes can be found in the 
"Busyout/Release Error Codes" section of this chapter.
 
 busyout trunk 78/1                             SPE A
                           COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01C1505   CO-TRK           78/01       PASS
 Command successfully completed