Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-121
display errors 
8
FORM Output
After valid options are entered by the technician, a hardware error report is 
displayed. The data displayed on this form will be:
Port
 The location of the maintenance object. For installed circuit 
packs, the location is displayed as 
"cabinet-carrier-[slot]-[circuit]." For Port Network-related objects, 
the location is displayed as "PN xx," where "xx" is the Port 
Network number. 
Maintenance Name
The logical name of the maintenance object which has had an 
error logged against it.
Alt Name
The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xx 
when the object is a private CO line, where xx is the private CO 
line group number.
Error Type
A code identifying the type of problem encountered for this 
maintenance object. Because the error code is generally specific 
to the individual maintenance object and the total number of error 
codes may be extensive, only the error number is displayed. The 
technician must use this error number in conjunction with the 
logical name information to determine the exact nature of the 
error.
Aux Data
Additional information concerning the maintenance object error 
condition which may be useful to the technician. Like the error 
type, this data will be specific to the maintenance object type. 
However, unlike the error code, only the most recent value of the 
auxiliary data will be retained for each error record.
First Occur
The month, day, hour, and minute (and second if the 
high-resolution command line option is used) that the error was 
first recorded.
Seq Cnt
Sequence Count - This number indicates the order of errors 
logged within a second for the time stamps associated with the 
first occurrence and last occurrence of an error. This information 
is displayed only if the "high-resolution" command line option is 
entered. There may be gaps for the sequence numbers within a 
given second since the last occurrence of an error may replace 
an existing entry that had been assigned the missing sequence 
number, and since sequence counts are also used with software 
event information not shown in the hardware error log.