Maintenance Commands and Trouble-Clearing Aids 
Page 8-161
enable administered-connection 
8
administered connections without interference from other maintenance 
processing. This commands restarts the processing of in-line errors for all or the 
selected administered connection.
Defaults
None.
Parameters
Help Messages
If the user presses HELP after entering "enable administered-connection", the 
following message will be displayed:
 Enter assigned administered connection number(1-128) or ’all’
Error Messages
If the administered connection number entered is not "all" and is non numeric, the 
following message is displayed:
 Identifier invalid
If the administered connection number entered is not within the valid range of 
connections, the following message is displayed:
 Entry out of range
If the connection number entered is not administered, the following message is 
displayed:
 Identifier not assigned
If the administered connection number entered is already enabled, the following 
message is displayed:
 Administered connection already enabled
If the software data cannot be sent to the SAT, the following message will be 
displayed:
 Error encountered, can’t complete request
If the command entered is in conflict with another currently executing command, 
then a message is displayed showing the login id of the conflicting user and the 
conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
ac number
The number of the administered connection being enabled.
all
IF "all" is entered then all administered connections are enabled.