Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-191
list marked-ports 
8
list marked-ports
This command lists all the ports that have been marked unusable.
Synopsis
list marked-ports [ print | schedule ]
Permissions
The following default logins may execute this command: bcms, browse, system 
technician, cust, inads, init, rcust.
Examples
list marked-ports
list marked-ports print
list marked-ports schedule
Description
The list marked-ports command displays all of the ports that have been marked 
unusable via the mark port command. For more information on the mark port 
command, refer to the 
 command description in this chapter.
A maximum of fifteen marked ports are displayed per page.
Defaults
No defaults.
Parameters
print
If specified, this parameter will cause the information displayed by this 
command to be sent to the printer attached to the terminal as well as to 
the screen.
schedule
When the "schedule" option is specified, the command is validated and 
then a scheduling form is displayed to allow the technician to schedule 
execution of the command. The command is then placed in the 
command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.