Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-203
list mst 
8
Version 1 ( default) displays a blank in the version field which is immediately after 
the MST message type field. Subsequent versions display the version number 
after the MST message type field and are connected with a ’-’. For example: 
Version 2 of the X.25 Application error/notification message has added the text of 
the pm state table stimulus which was ignored.
Version 1 of MST message type 0xA2 would appear on the ’list mst’ output:
Version 2of MST message type 0xA2 would appear on the ’list mst’ output:
Vector Trace 
Message type: 0x10
Message format:
Vector Event Trace (D92 Only)
Message type:
0x11
Number
Date/Time
Type
Message
1
11:41:22:425
A2
17 10
Number
Date/Time
Type
Message
90
12:41:14:112
A2-02
17 10 21 03 32 05 01 80
 Message[1-4]
= call identifier (CID) (defined in $BASEPJ/hdrs/capro.h)
Message[5-6]
= vector number (defined in $BASEPJ/hdrs/dpm_calls.h)
Message[7]
= step number (defined in $BASEPJ/hdrs/callr.h)
Message[8]
= step type (defined in $BASEPJ/hdrs/dpm_calls.h)
Message[9]
= step state (defined in $BASEPJ/hdrs/dpm_calls.h)
Message[10-12]
= VDN
Message[13]
= port network number
Message[14]
= endpoint number
Message[15]
= angel number
Message[16]
= circuit number
Message[17-20]
= trunk number
Message[21+]
= auxiliary data (based on step type)