Maintenance Commands and Trouble-Clearing Aids 
Page 8-511
status system 
8
3rd-cabinet
all-cabinets
If the system technician presses 
HELP
 after entering "status system cabinet", 
where "cabinet" is one of the object described above, the following message will 
be displayed:
[’print’]
Error Messages
None
Output
!
CAUTION:
The purpose of this command is to provide general information about the 
cabinet status. This information may not display correctly when the cabinet 
is in a transient period. In this case, wait for 1 minute and enter the 
command again.
1. SIMPLEX SPE MODES
active
 The 
1A
SPE in a simplex system is always the 
active
 SPE.
<blank>
 The 
1B
SPE in a simplex system always displays 
<blank>
 
indicating there is no 1B SPE.
2. DUPLEX SPE MODES
The modes for the active and standby SPE in a system with the duplication 
option are different.
3. DUPLEX ACTIVE SPE MODES
active
 This SPE is performing its designed functions for the system 
as the active SPE.
active/override-on
 This SPE is performing its designed functions 
for the system as the active SPE, however, this SPE is active 
because it was forced active via a 
reset system interchange 
health-override
 command.
selected
 This SPE is the "active" SPE and is performing its 
designed functions for the system, however, the SPE select 
switches will 
not
 allow this SPE to become the standby SPE.
SPE
The identifier of the Switch Process Element (SPE). Valid identifiers are 
1A
 or 
1B
.
MODE
The modes of an SPE are different for simplex systems versus those for 
systems with the duplication option.