Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-549
test analog-testcall 
8
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the command that was entered 
was "test analog-testcall trunk 78".
Feature Interactions
Additional data is available after running a test. See the list measurements 
test-calls command for details on how to access the additional data.
If the trunk is in use by call processing the test will abort.
If the trunk is in use by maintenance, the test will queue and will run when the 
current maintenance activity finishes.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains xxx/yyy when the object is a trunk, where xxx is the 
trunk group number and yyy is the member number.
Test No.
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO (for example, CO_TRK Transmission Tests 
(#844-849).
 
 test analog-testcall trunk 78
                            TEST RESULTS
           
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01C1505   CO-TRK             78/1     845      PASS
   01C1507   CO-TRK             78/2     845      PASS
 Command Successfully Completed