Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-553
test board 
8
Output
The responses display on a test-by-test basis with one line of data displayed for 
each test result.
For the following output example, the command entered was "test board 1c07".
Feature Interactions
Destructive long tests on a Switch Node Interface (SNI) board are not allowed 
unless the board has been busied out.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test board 01C07 short
                            TEST RESULTS
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01C07     ANL-BD                      51       PASS
   01C07     ANL-BD                      52       PASS
   01C0703   ANL-LINE                    35       PASS
   01C0703   ANL-LINE                    48       PASS
   01C0703   ANL-LINE                    36       PASS
   01C0701   ANL-LINE                    35       PASS
   01C0701   ANL-LINE                    48       PASS
   01C0701   ANL-LINE                    36       PASS
   01C0702   ANL-LINE                    35       PASS
   01C0702   ANL-LINE                    48       PASS
   01C0702   ANL-LINE                    36       PASS