Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-569
test ds1-loop 
8
Examples
test ds1-loop 01c08
test ds1-loop 1-3c03 cpe-loopback-jack
test ds1-loop 1-3c03 cpe
test ds1-loop 10c03 end
test ds1-loop 02d12 fa
test ds1-loop 02d12 inj
Description
The test ds1-loop command will validate that the board exists at the specified 
location, that the board is a TN464F or TN767E or later suffix DS1 Interface 
board. Based on the command parameter, a long-duration loopback/span test or 
series of short-duration loopback tests will be executed.
Long-duration loopback tests execute for an extended period of time until the 
system technician terminates it. Short-duration loopback tests return the result of 
the test to the screen when finished executing. The "list measurements ds1 
summary" command should be used to monitor the status of a long-duration 
loopback/span test. 
Defaults
The default for the command is ds1/csu-loopback-tests.