Page 8-572
test ds1-loop 
8
If the "inject-single-bit-error" parameter is selected, but no CPE Loopback Jack, 
far-end CSU, or one-way span test is active on the DS1 circuit pack, then the 
following message will be displayed:
 Parameter valid only if a loopback/span test is active on the DS1
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the board in cabinet 1, carrier c, 
slot 7 is a TN767E DS1 board. The command that was entered was "test ds1-loop 
1c07."
Feature Interactions
Loopback or span tests will not be allowed on DS1 boards unless the board has 
been busied out.
Only one of the CPE Loopback Jack, far-end CSU, one-way span, or DS1/CSU 
loopback tests may be active at any given time on a DS1 span.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object.
Test No
The actual test that is being executed.
Result
The result of the individual test - "PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD".
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
  
 test ds1-loop 01C07 ds1/csu-loopback-tests
                                  TEST RESULTS
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01C07     DS1-BD                      1209     PASS
   01C07     DS1-BD                      1210     PASS
   01C07     DS1-BD                      1211     PASS
 Command Successfully Completed