DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-578
test eda-external-device-alrm 
8
Parameters
Examples
test eda-external-device-alrm all
test eda-external-device-alrm all schedule
test eda-external-device-alrm physical 1major r 10
test eda-external-device-alrm physical 2c1101 c
physical location
In addition to entering the word "physical" the system technician 
must specify the physical location. For an administered external 
device alarm analog line port, a "physical location" represents the 
physical position of the port to be tested and is entered as 
"
UUcSSpp
" where "
UU
" represents the cabinet number (1-MAX_
CABS), "
c
" represents the carrier, "
SS
" represents the slot position, 
and "
pp
" represents the circuit.
Since the "maintenance board" alarm connections connect to 
control carrier boards that are in unnumbered slots, the standard 
port format cannot be used to designate these alarm connections. 
The special ports 
UUmajor
 and 
UUminor
 are used designate the 
major or minor maintenance board alarm connection for cabinet 
UU
.
NOTE:
The major/minor designation specifies the pair of wires, not 
the alarm level associated with the connection (
i.e
. the "major" 
port can be administered as a major, minor or warning alarm 
and the "minor" port can be administered as a major, minor or 
warning alarm).
The "all" location is used to test all administered external device 
alarm ports on analog line boards and maintenance boards.
repeat number
The "number" specifies how many times the “test physical location” 
is to be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until 
the alarm (if one exists against the maintenance object) is cleared or 
a single test in the sequence fails. If no alarms are registered 
against the maintenance object then the test sequence will be 
exercised only once.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed 
in the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specifications [1] for more details.