Maintenance Commands and Trouble-Clearing Aids 
Page 8-581
test environment 
8
NOTE:
The processor carrier and its duplicate if present as well as any EPN 
control carrier or an SCC carrier will not be recycled. All port carriers are 
recycled, and service is interrupted for each port carrier. If a carrier 
containing an active EI is recycled, communications with that cabinet will 
be disrupted. If a carrier containing an active tone-clock board is recycled, 
all ports in the cabinet or port network will have service disrupted.
Defaults
The default cabinet is cabinet 1. Defaults for the remaining parameters are short 
with a repeat of 1.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test environment," the 
following message will be displayed:
Enter [cabinet(1-3)],[’long’ or ’short’],
[’repeat’(1-100) or ’clear’],[’schedule’]
location
The location the cabinet number. The cabinet number is one or two 
digits from 1 to 3 with leading zeros allowed. Cabinet 1 is the PPN with 
2-3 referring to some optional EPN.
short
This will cause the command to execute a series of nondestructive 
diagnostic tests.
long
This will execute a more comprehensive and longer version of the 
diagnostic tests. This includes both destructive and nondestructive 
tests for this command.
repeat number
The "number" specifies how many times each test in the sequence is 
to be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The long clear option forces a clear of all alarms if no errors are 
encountered during testing. The short clear option only clears alarms 
pertinent to tests in the short sequence.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.