Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-601
test isdn-testcall 
8
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the command that was entered 
was "test interface a1".
Feature Interactions
None.
test isdn-testcall
This command starts an outgoing ISDN-PRI test call.
Synopsis
test isdn-testcall group number
/member number
 
minutes minute number 
schedule
Port
The port address (cabinet-carrier-slot) of the maintenance object 
that is being tested.  With this particular maintenance object, the 
port address represents the carrier associated with the particular 
processor interface board.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
Not applicable.
Test No
The actual test that is being executed.
Result
The result of the individual test - "PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test interface a1
                               TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result      Error Code
   01A1    PI-SCI                      231      PASS
   01A1    PI-BD                       52       PASS
 Command Successfully Completed