Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-619
test memory 
8
If the system technician presses 
HELP
 after entering "test disk" on a duplex SPE 
system the following message will be displayed:
Enter [cabinet(1)];carrier(A-B),
[’long’ or ’short’],   [’repeat’ (1-100) 
or ’clear’], [’schedule’]
Error Messages
For SPE duplex systems, if no carrier is entered on the command line, the 
following message will be displayed:
A carrier must be specified for duplex systems
For any system, if the length of the user entered parameter exceeds five (5), the 
following message will be displayed:
Entry invalid
On any system, if any cabinet other than "1" or "01" is specified, the following 
message will be displayed:
Only cabinet ’1’ may be specified for this command
If a carrier is entered which is not valid for the current system configuration (for 
example, anything other than "A" or "B" for SPE duplex and anything other than 
the ’a’ carrier for SPE simplex), the following message will be displayed:
Carrier out of range;
Enter ’a’ if SPE simplex, ’a’ or ’b’ if SPE duplex
If the standby SPE was specified, and it does not respond, the following 
message will be displayed:
Standby SPE not available;
for information use ’status system’
If an invalid position number is entered, the following message will be displayed:
Board position is invalid
If a non administered circuit pack location is entered, the following message will 
be displayed:
Memory Board not assigned
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict