Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-669
test synchronization 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test synchronization", the 
following message will be displayed:
Enter [’long’ or ’short’], [’repeat’ (1-100)
 or ’clear’], [’schedule’]
Error Messages
If there are no tests found for synchronization maintenance object, the following 
message will be displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
short
This causes the command to execute a series of nondestructive 
diagnostic tests.
long
This executes a more comprehensive and longer version of the 
diagnostic tests. This involves both destructive and nondestructive 
tests. For the synchronization MO, the same nondestructive test is run 
for both the short and long tests: test 417. If stratum-3 synchronization 
is administered, an additional nondestructive test (649) is also run.
repeat number
The "number" specifies how many times each test in the sequence is 
repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against synchronization maintenance object) is 
cleared or a single test in the sequence fails. If no alarms are 
registered against synchronization maintenance object then the test 
sequence will be exercised only once. The long clear option forces a 
clear of all alarms if no errors are encountered during testing. The short 
clear option only clears alarms pertinent to tests in the short sequence.
schedule
When the "schedule" option is specified, the command is validated and 
then a scheduling form is displayed to allow the technician to schedule 
execution of the command. The command is then placed in the 
command queue and is executed at the specified time. The information 
displayed by the command is sent to the system printer instead of the 
screen. Refer to the Report Scheduler and System Printer feature 
specification [1] for more details.