Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Packet Bus Fault Isolation and Correction 
Page 9-12
The Maintenance/Test Circuit Pack (TN771D) 
9
4. D8W 8-wire modular cable of an appropriate length to connect the 258A 
on the back of the cabinet to the 355A adapter. The relevant COMCODE is 
determined by the length of the cable, as follows:
103 786 786 (7 feet)
103 786 802 (14 feet)
103 786 828 (25 feet)
103 866 109 (50 feet)
Slot Selection for Standalone Mode
When selecting a carrier slot to use for standalone mode in a port network that 
does not already contain a TN771, keep the following points in mind:
A port circuit slot (indicated by a purple label) should be used.
-5 volt power supply must be available in the carrier. This section 
describes the power supply configurations that provide this power supply.
It is preferable that the slot chosen is in the A carrier if a free slot that 
matches the criteria presented in the first two items of information in this 
list is available. 
Entering and Exiting Standalone Mode
NOTE:
When in standalone mode, the red LED on the TN771 is lit. This function is 
correct, and it serves as a reminder to remove the TN771 from standalone 
mode.
!
CAUTION:
The TN771 in standalone must be the ONLY TN771 in the port network. If a 
TN771 is already in the port network, place that TN771 in standalone mode. 
Do not insert a second TN771 into standalone mode. System behavior is 
rendered as undefined if this is done. In addition, the system is not able to 
detect the extra circuit pack in this case because a TN771 in standalone 
mode is invisible to the SPE.
!
CAUTION:
If the TN771 Packet Bus port has reconfigured the Packet Bus in a switch 
with a High or Critical Reliability system, (indicated by error type 2049 
against PKT-BUS), placing the Maintenance/Test in standalone mode 
causes a loss of service to the Packet Bus. This is true because 
reconfiguration is not performed in standalone mode. Therefore, this 
procedure should be considered a service-disrupting procedure.