Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Packet Bus Fault Isolation and Correction 
Page 9-15
The Maintenance/Test Circuit Pack (TN771D) 
9
Using Standalone Mode in Packet Bus Fault 
Isolation and Correction
When the TN771 is in standalone mode, three commands can be used at the 
terminal:
 
ds
 displays the current state of the Packet Bus leads.
dsa
 toggles auto-report mode on and off. In auto-report mode, the state of 
the Packet Bus leads are displayed and the terminal beeps whenever a 
change occurs.
?
 displays the available commands.
 presents an example of a standalone mode display. In the display, an 
‘S’ indicates a shorted lead, an ‘O’ indicates an open lead, and a blank indicates 
no fault.
Figure 9-2.
Example Standalone Mode Display
The information within a standalone mode display is used in the Packet Bus Fault 
Correction procedures that follow. The TN771 display indicates the specific 
leads on the backplane to examine for bent or damaged pins. 
 shows 
the location of the packet bus leads on the backplane as viewed from the front of 
the carrier, while 
 shows the same slot as viewed from the back of the 
carrier.
NOTE:
This information is available only from the standalone mode and with an 
on-site connected terminal. This information is not available from the 
Manager I, and, thus, it is not available remotely. This is not a concern, 
inasmuch as this information cannot be used effectively if testing is not on 
site.
L L L L L L L L L L H H H H H H H H H H S S S L
P 0 1 2 3 4 5 6 7 8 P 0  1  2  3  4  5  6  7  8 S F B F
____________________________________________________________________________________________________
S S 
O
Command: