Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-28
ADX16D-B (16 Port AUDIX Circuit Pack) 
10
ADX16D-B (16 Port AUDIX Circuit 
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 DEFINITY 
AUDIX circuit pack combination operating in 16 port mode digital (DP). For 
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. 
Port-level maintenance is covered by ADX16D-PT.
DEFINITY AUDIX consists of 2 circuit packs that occupy 5 slots on a port carrier. 
The tests described in this manual apply only to switch-side maintenance which 
tests circuit pack components related to the TDM bus interface. The AUDIX 
system has an extensive maintenance strategy of its own that is described in 
DEFINITY AUDIX System Maintenance
, 585-300-110.
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). 
SS is the number of the slot in which the circuit pack
resides (01 to 21).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command To Run
1
Full Name of MO
ADX16D-B
MINOR
test board PCSS sh
AUDIX Circuit Pack
ADX16D-B
WARNING
test board PCSS sh
AUDIX Circuit Pack