Siemens TX150 S6 User Manual
D2559 (TX150 S6)
Technical Manual
23
Features
LEDs
The LEDs have the following meaning:
If the server has been powered off (power-plugs must be disconnected) it is
possible to indicate the faulty component by pressing the CSS button.
possible to indicate the faulty component by pressing the CSS button.
LED Indicator
Meaning
A - GEL
(Global Error
LED)
(Global Error
LED)
amber
indicates a prefailure
amber flashing indicates a failure. Reasons for a failure
may be:
- overheating of one of the sensors
- sensor defect
- fan defect
- CPU error
- Software detected an error
- overheating of one of the sensors
- sensor defect
- fan defect
- CPU error
- Software detected an error
B - CSS
(Customer Self
Service)
(Customer Self
Service)
yellow
indicates a prefailure
yellow flashing
indicates a failure
C - Identification blue
server is identified via ServerView
D - memory
amber
memory module failure
E - CPU/system
fans
fans
amber
fan failure
F - controller
amber
controller failure
G - iRMC healthy green blinking
iRMC (integrated Remote Management
Controller) is okay
Controller) is okay