Reseat the memory modules in their sockets. See "Installing Memory Modules" on page 65.
8
Replace the memory cooling shroud. See "Replacing the Memory Cooling Shroud" on page 53.
9
10
Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
11
Enter the System Setup program and check the system memory setting. See "Using the System Setup 
Program" on page 31.
If the amount of memory installed does not match the system memory setting, then perform the following 
steps:
a
Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
b
 
NOTE: 
Several configurations for memory modules exist; see "General Memory Module Installation 
c
Swap the memory module in socket 1 with another of the same capacity. See "Installing Memory 
Modules" on page 65.
d
e
Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
f
As the system boots, observe the monitor screen and the indicators on the keyboard.
12
Perform the following steps:
a
Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
b
c
Perform step c through step f in step 11 for each memory module installed.
Troubleshooting an Optical Drive
Problem
System cannot read data from a CD or DVD in an optical drive.
Optical drive indicator does not blink during boot.
 
NOTE: 
DVD devices are data only.
Action
 
CAUTION: 
Many repairs may only be done by a certified service technician. You should only perform 
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or 
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your 
warranty. Read and follow the safety instructions that came with the product.