DCS dCS 974 User Manual

Page of 131
dCS 974 User Manual
 Manual for Software Version 1.0x
dCS Ltd 
May 2001
Manual part no: DOC1241121A1
Page 11
Document No: OS-MA-A0124-112.1A1
Contact 
dCS
 on + 44 1799 531 999 
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
Step 1 – Selecting an Input
TOP LEVEL
Sample Rate Conversion
Audio Input Select
AES 1
 Default
Sync Source
AES 2
Multi-Channel Sync
AES 3
Input Sample Rate
AES 4
Dual AES (1+2)
Quad AES
SPDIF1 (RCA)
SPDIF2 (BNC
SPDIF3 (TOS)
PCM SDIF-2
DSD SDIF-2
DSD Quad
Figure 1 – Audio Input Selection
Choose one of the following five sections:
Connecting to a Single AES or SPDIF source
do this: 
Connect your source equipment to the matching input on the dCS 974 rear panel
using suitable cables. An AES3 source (XLR connector) may be connected to
any of the four AES/EBU inputs.
do this: 
Press the 
 button twice to enter first the 
Sample Rate Conversion
 menu,
then the 
Audio Input Select
 menu. Use the rotary control to scroll down the list
until the cursor is beside your chosen input (either 
AES 1, AES 2, AES 3, AES 4,
SPDIF 1 (RCA), SPDIF2 (BNC)
 or 
SPDIF3 (Toslink)
). Press the 
Set
 button.
The screen will change back to the 
Sample Rate Conversion
 menu. Proceed
to Step 2.
Connecting to a PCM SDIF-2 source
do this: 
Connect the SDIF-2 output on your source equipment to the upper block of
DSD/SDIF connectors on the dCS 974 rear panel using 3 coax cables. Connect
CH1 out to 
CH1 IN
, CH2 out to 
CH2 IN
, CLK out to 
WCLK IN
. Fit a 75
Ω
terminating plug to the nearby 
LOOP OUT
 connector.
do this: 
Press the 
 button twice to enter first the 
Sample Rate Conversion
 menu,
then the 
Audio Input Select
 menu. Use the rotary control to scroll down the list
until the cursor is beside 
PCM SDIF-2
. Press the 
Set
 button to select it.
The screen will change back to the 
Sample Rate Conversion
 menu. Proceed
to Step 2.