Syncing to an AES/EBU Reference
If you want to synchronise your system to an AES/EBU Reference from a
Master Clock (such as the dCS 992) or other stable source, do the following:
Master Clock (such as the dCS 992) or other stable source, do the following:
do this:
Set the Master Clock sample rate to match the source (probably 44.1 or
48kS/s).
48kS/s).
do this:
Connect either an AES/EBU or Wordclock output from the Master Clock to the
clock input on the source equipment and ensure it is locked.
clock input on the source equipment and ensure it is locked.
do this:
Connect another AES/EBU output from the Master Clock to the
AES Ref Loop
IN
connector on the dCS 974 rear panel.
do this:
Scroll down the
Sample Rate Conversion
menu to
Sync Source
and press
the
→
→
→
→
button. Scroll down the list to
AES Loop Terminated
and press
Set
.
The
Unlocked
indicator will light for a few seconds, then turn off as the unit
re-locks.
do this:
Proceed to Step 3.