Format Conversion
The default setting is 
SRC
 mode on, 
FC
 mode Off.  To turn 
FC
 mode on, select
Format Conversion
 and press 
.  The menu below will appear:
Pressing 
Set
 will toggle the state from 
Off
 to 
On
. The unit will check to see if
the 
Output Sample Rate
 is the same as the 
Input Sample Rate
, and if it is
not it asks you to press 
Set
 to change the 
Output Sample Rate
, or any other
button to cancel the attempt to turn 
FC mode on.
On returning to the main menu, 
Sample Rate Conversion
 is shown as
disabled:
To re-enter 
SRC
 mode, you have to set 
Pure Format Conversion 
to 
Off
.
Error Monitoring
Error monitoring on the input signal can be implemented for CRC, Parity and
Valid bits in the AES3 and SPDIF message streams. This menu covers
resetting the monitors, and is only available for PCM inputs – the entry
disappears for DSD inputs.
Test
The unit can be used as a very high purity signal generator, as well as
performing self test functions, via this menu.
Info
This menu displays information about the unit, for support purposes