DCS dCS 974 User Manual
dCS 974 User Manual
Manual for Software Version 1.0x
dCS Ltd
May 2001
Manual part no: DOC1241121A1
Page 39
Document No: OS-MA-A0124-112.1A1
Contact
dCS
on + 44 1799 531 999
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
Format Conversion
The default setting is
SRC
mode on,
FC
mode Off. To turn
FC
mode on, select
Format Conversion
and press
→
→
→
→
. The menu below will appear:
Pressing
Set
will toggle the state from
Off
to
On
. The unit will check to see if
the
Output Sample Rate
is the same as the
Input Sample Rate
, and if it is
not it asks you to press
Set
to change the
Output Sample Rate
, or any other
button to cancel the attempt to turn
FC mode on.
On returning to the main menu,
Sample Rate Conversion
is shown as
disabled:
To re-enter
SRC
mode, you have to set
Pure Format Conversion
to
Off
.
Error Monitoring
Error monitoring on the input signal can be implemented for CRC, Parity and
Valid bits in the AES3 and SPDIF message streams. This menu covers
resetting the monitors, and is only available for PCM inputs – the entry
disappears for DSD inputs.
Valid bits in the AES3 and SPDIF message streams. This menu covers
resetting the monitors, and is only available for PCM inputs – the entry
disappears for DSD inputs.
Test
The unit can be used as a very high purity signal generator, as well as
performing self test functions, via this menu.
performing self test functions, via this menu.
Info
This menu displays information about the unit, for support purposes