DCS dCS 974 User Manual

Page of 131
dCS 974 User Manual
 Manual for Software Version 1.0x
dCS Ltd 
May 2001
Manual part no: DOC1241121A1
Page 59
Document No: OS-MA-A0124-112.1A1
Contact 
dCS
 on + 44 1799 531 999 
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
None 
Disables the 
Peak Hold
 feature.
320ms thru 1600ms
 Sets 
the 
Peak Hold
 time.
Infinite
 
Sets an infinite 
Peak Hold
 time.
Reset 
Resets the 
Peak Hold
 segments to the current
peak.
Select the required option and press 
Set
. Infinite allows the highest peaks in a
track or long passage to be displayed – you might want this to do a manual
maximise:
do this: 
Select 
Infinite 
and press 
Set.
do this: 
At the start of the track, select 
Reset
 and press 
Set
.
do this: 
Press 
Status
 to display the meter.
do this: 
At the end of the track the highest peaks will be displayed.
do this: 
Select 
Reset
 again and press 
Set
 to clear the peak readings.
Using the dCS 974 to monitor a track
If you just want to use the dCS 974 as a level monitoring device, you can control
the bandwidth you monitor by setting the output data rate – 44.1kS/s will give
approximately 20kHz bandwidth, whereas 96kS/s will give approximately 40
kHz bandwidth.
The meters can be used to monitor DSD by setting a DSD to PCM conversion,
and using the appropriate output data rate.
Watch Out for this One!
If the unit is tested with sine waves at frequencies which divide almost exactly
into the sample rate (e.g. 6.001kHz signal, 48 kS/s sampling frequency), the
segments on the right hand side of the meter will flicker. This effect disappears
if the signal frequency is changed by about 10Hz and so it is not a problem
when monitoring music. It is caused by the signal beating with the sample rate.