CHAPTER 26: 16-BIT INPUT CAPTURE 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : 16-BIT INPUT CAPTURE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
12 
4.1.3. LIN SYNCH FIELD Switching Register : LSYNS 
The bit configuration of the LIN SYNCH FIELD switching register is shown below. 
The LIN SYNCH FIELD switching register (LSYNS) is used for LIN linkage control. 
 
  LSYNS: Address 1283
H
 (Access: Byte, Half-word, Word) 
 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
Reserved 
LSYN3 
LSYN2 
LSYN1 
LSYN0 
Initial value 
Attribute 
R0,W0 
R0,W0 
R0,W0 
  R0,W0 
R/W 
R/W 
R/W 
R/W 
 
 
[bit7 to bit4] Reserved 
Always write 0 to these bits. 
 
[bit3 to bit0] LSYN3 to LSYN0: Input capture 3 to 0 input selection 
LSYN3 to LSYN0 
Function 
External pin input (ICU3 to ICU0) 
Input Lin Synch Field detection signals from the multi-function serial 
interface ch.3 to ch.0. 
 
 
These bits are used to enable Lin Synch Field from the multi-function serial interface ch.3 to ch.0. 
 
 
 
 
 
 
 
 
 