CHAPTER 28: REAL-TIME CLOCK(RTC) 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : REAL-TIME CLOCK(RTC) 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
[bit13] INTE2 : 1 hour interrupt request enable 
INTE2 
Operation 
1 hour interrupt request disabled 
1 hour interrupt request enabled 
 
[bit12] INT2 : 1 hour interrupt request flag 
INT2 
State 
Read 
Write 
1 hour interrupt request not generated 
Flag clear 
1 hour interrupt request generated 
This does not affect the operations 
When overflow occurs in the minute counter, the flag will be set to "1". 
[bit11] INTE1 : 1 minute interrupt request enable 
INTE1 
Operation 
1 minute interrupt request disabled 
1 minute interrupt request enabled 
 
[bit10] INT1 : 1 minute interrupt request flag 
INT1 
Operation 
Read 
Write 
1 minute interrupt request not generated 
Flag clear 
1 minute interrupt request generated 
This does not affect the operations 
When overflow occurs in the second counter, the flag will be set to "1". 
[bit9] INTE0 : 1 second interrupt request enable 
INTE0 
Operation 
1 second interrupt request disabled 
1 second interrupt request enabled 
 
[bit8] INT0 : 1 second interrupt request flag 
INT0 
State 
Read 
Write 
1 second interrupt request not generated 
Flag clear 
1 second interrupt request generated 
This does not affect the operations 
When overflow occurs in the 0.5 second counter, the flag will be set to "1". 
MB91520 Series
MN705-00010-1v0-E
1048