CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
38 
4.2.4. 
Receive Data Register/Transmit Data Register: 
RDR/TDR 
The receive data register and transmit data register are located within the same addresses. When read, it 
functions as the receive data register and when written, it functions as the transmit data register. When FIFO 
is enabled, the address of RDR/TDR will be the address for reading/writing FIFO. 
 Read 
 RDR0n(n=0 to 11): Address Base addr + 06
H
 (Access: Byte, Half-word, Word) 
 
15 
14 
13 
12 
11 
10 
bit 
D8 
 
Initial value 
R0,WX  R0,WX  R0,WX  R0,WX  R0,WX  R0,WX  R0,WX 
R,W 
Attribute 
 
bit 
D7 
D6 
D5 
D4 
D3 
D2 
D1 
D0 
 
Initial value 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
R,W 
Attribute 
The receive data register (RDR) is a 9-bit data buffer register for serial data reception. 
  Serial data signals sent to the serial input pin (SIN pin) are converted in the shift register and stored in 
the receive data register (RDR). 
  Depending on the data length, "0" is inserted in the upper bit as shown below. 
 
 
Data length  D8  D7  D6  D5  D4  D3  D2  D1  D0 
9 bits 
8 bits 
7 bits 
6 bits 
5 bits 
(X is the reception data bit) 
 
  When the received data is stored in the receive data register (RDR), the reception data full flag bit 
(SSR:RDRF) will be set to "1". When reception interrupts are enabled (SSR:RIE=1), a reception 
interrupt request will be generated. 
  The receive data register (RDR) should be read out when the reception data full flag bit (SSR:RDRF) is 
"1". The reception data full flag bit (SSR:RDRF) will be automatically cleared to "0" when the receive 
data register (RDR) has been read out. 
  In case a reception error occurs (SSR: PE, ORE or FRE is "1"), data in the receive data register (RDR) 
will become invalid. 
  In operation mode 1 (multi-processor mode), the operation will be 7-bit or 8-bit long. The AD bit 
received will be stored at the D8 bit. 
  For the 9-bit long transfer and in operation mode 1, RDR will be read in 16-bit access mode. 
Notes: 
  When you use reception FIFO, if received data in the reception FIFO reaches specified number, "1" will 
be set to RDRF. 
  When you are using reception FIFO, if the reception FIFO becomes empty, RDRF will be cleared to "0". 
  If a reception error occurs (SSR: PE, ORE, or FRE is "1") while using reception FIFO, the reception 
FIFO enable bit will be cleared. As a result, data received will not be stored at the reception FIFO. 
 