CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
85 
Bit name 
Function 
bit3  ORE: 
Overrun error flag bit 
"0" Read: No overrun error 
"1" Read: There is an overrun error 
 
  If an overrun error occurs while a reception is in progress, this bit will be 
set to "1". To clear this bit, write "1" to the REC bit of the serial status 
register (SSR). 
  When the ORE bit and RIE bit are set to "1", a reception interrupt 
request will be output. 
  If this flag is set, data contained in the receive data register (RDR) 
becomes invalid. 
  When this flag is set while using the reception FIFO, the reception FIFO 
enable bit will be cleared. As a result, the reception data will not be 
stored in the reception FIFO. 
bit2  RDRF: 
Reception data full flag bit 
"0" Read: Receive data register (RDR) is empty 
"1" Read: Receive data register (RDR) contains data. 
 
  The flag indicates the state of the receive data register (RDR). 
  When received data is loaded in RDR, this flag will be set to "1" and 
when RDR is read out, it will be cleared to "0". 
  When the RDRF bit and RIE bit are set to "1", a reception interrupt 
request will be output. 
  While using reception FIFO, the RDRF will be set to "1" once the 
reception FIFO has received the specified number of data sets. 
  While using reception FIFO, the bit will be cleared to "0" once the 
reception FIFO becomes empty. 
bit1  TDRE: 
Transmission data empty 
flag bit 
"0" Read: Transmit data register (TDR) contains data. 
"1" Read: Transmit data register (TDR) is empty 
 
  The flag indicates the state of the transmit data register (TDR). 
  When a transmit data is written to TDR, this flag turns to "0", which 
indicates that a valid data exists in the TDR. Once a transmission starts 
after data being loaded to the transmit shift register, the bit will be set to 
"1", which indicates that the TDR does not contain any valid data. 
  When the TDRE bit and the TIE bit are set to "1", a transmission 
interrupt request will be output. 
  When you set UPCL bit of the serial control register (SCR) to "1", the 
TDRE bit will be set to "1". 
  For details of the timing of setting/resetting the TDRE bit while using 
transmission FIFO, see Section "7.1.5 Interrupts When Using 
Transmission FIFO and Flag Setting Timing". 
bit0  TBI: 
Transmission bus idle flag 
bit 
"0" Read: Transmitting 
"1" Read: No transmission operation 
 
  This bit indicates that LIN-UART has no transmission in progress. 
  When transmission data has been written to the transmit data register 
(TDR), this bit will become "0". 
  If the LIN Break field is set (LBR=1), this bit will be cleared to "0". 
  When the transmit data register (TDR) is empty (TDRE=1) and no 
transmission is in progress, this bit will be set to "1". 
  If the LIN Break field transmission has ended, and the transmit data 
register is empty, this bit will be set to "1". 
  When this bit is "1" and transmission bus idle interrupts are enabled 
(SCR:TBIE=1), a transmission interrupt request will be output. 
MB91520 Series
MN705-00010-1v0-E
1398