Fujitsu FR81S User Manual

Page of 2342
CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
93 
[bit5] TRGE: External trigger enable bit 
This bit is used to select how to activate the serial timer.
 
TRGE 
Description 
When the serial timer enable bit (TMRE) is changed from 
"0" to "1", the serial timer will start operation. 
When the serial timer enable bit (TMRE) is set to "1", and 
an edge of the external trigger set by the trigger select bits 
(TRG1, 0) is detected, the serial timer will start operation. 
 
Notes: 
  This bit can be changed only when the serial timer enable bit (TMRE) is set to "0". 
  When the serial timer enable bit (TMRE) is set to "0", the serial timer will not start operation, even if an 
edge of the external trigger set by the trigger select bits (TRG1, 0) is detected. 
 
[bit4 to bit1] TDIV3-0: Timer operating clock division bits 
These bits are used to set the division ratio of the serial timer.
 
 
TDIV3 TDIV2 TDIV1 TDIV0 
Timer operating clock 
Division 
ratio 
φ
8MHz 
φ
10MHz 
φ
16MHz 
φ
20MHz 
φ
24MHz 
φ
32MHz 
φ 
125ns 
100ns 
62.5ns 
50ns 
41.67ns  31.25ns 
φ
/2 
250ns 
200ns 
125ns 
100ns  83.33ns  62.5ns 
φ
/4 
500ns 
400ns 
250ns 
200ns  166.67ns  125ns 
φ
/8 
1µs 
800ns 
500ns 
400ns  333.33ns  250ns 
φ
/16 
2µs 
1.6µs 
1µs 
800ns  666.67ns  500ns 
φ
/32 
4µs 
3.2µs 
2µs 
1.6µs 
1.33µs 
1µs 
φ
/64 
8µs 
6.4µs 
4µs 
3.2µs 
2.67µs 
2µs 
φ
/128 
16µs 
12.8µs 
8µs 
6.4µs 
5.33µs 
4µs 
φ
/256 
32µs 
25.6µs 
16µs 
12.8µs  10.67µs 
8µs 
φ
: Bus clock 
Notes: 
  These bits can be changed only when the serial timer enable bit (TMRE) is set to "0". 
  Settings other than those listed above are prohibited. 
 
MB91520 Series
MN705-00010-1v0-E
1406