4.4.8. 
Sync Field Upper Limit Register: SFUR   
The Sync Field upper limit register (SFUR) is used to set the upper limit of the value which can be set to the 
baud rate generator register for automatic baud rate adjustment. 
 SFURn(n=0 to 11) : Address Base addr + 0E
(Access: Byte, Half-word, Word) 
 
15 
14 
13 
12 
11 
10 
bit 
TU14 
TU13 
TU12 
TU11 
TU0 
TU9 
TU8 
 
Initial value 
R0,WX 
R/W 
R/W 
R/W 
R/W 
R/W 
R/W 
R/W 
Attribute 
 
bit 
TU7 
TU6 
TU5 
TU4 
TU3 
TU2 
TU1 
TU0 
 
Initial value 
R/W 
R/W 
R/W 
R/W 
R/W 
R/W 
R/W 
R/W 
Attribute 
[bit15] Undefined 
The read value is "0". Writing has no effect on the operation. 
[bit14 to bit0] TU14-0: Upper limit bits 
These bits are used to set the upper limit of the value which can be set to the baud rate generator register 
(BGR) for automatic baud rate adjustment. 
When the automatic baud rate adjustment bit (SACSR:AUTE) is set to "1" and the slave mode is selected 
(SCR:MS="1"), the value of the serial timer register (STMR) will be set to the baud rate generator register 
(BGR), if the value of the serial timer register (STMR) after Sync Field is received is smaller than these bits 
and larger than the Sync Field lower limit register (SFLR). 
Note: 
These bits can be changed when the automatic baud rate adjustment bit (SACSR:AUTE) is set to "0". 
 