Fujitsu FR81S User Manual

Page of 2342
CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
5. Operation of UART 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
164 
 
 Transmission Operation by External Trigger 
If the synchronous transmission is enabled (SACSR:TSYNE="1"), the external trigger is enabled 
(SACSR:TRGE="1"), the timer comparison register (STMCR) is set to (0000)H, the transmission is 
enabled (SCR:TXE="1"), and the valid data exists (SSR:TDRE="0"), the transmission operation by the 
external trigger starts. 
Starting the transmission operation by the external trigger operates as shown below: 
1.  If the edge of the external trigger which is set with the trigger selection bit (SACSR:TRG1, 0) is 
detected, the transmission operation starts immediately. It continues to send the transmission data while 
the transmission bus idle flag (SSR:TB1) is "0". 
2.  If the transmission data is written to the transmission data register (TDR) after the transmission bus idle 
(SSR:TB1="1"), the transmission operation starts when the edge of the external trigger which is set 
with the trigger selection bit (SACSR:TRG1, 0) is detected. 
Figure 5-17 Transmission Operation by External Trigger (TRG1="0", TRG0="1") 
0
STMR
STMCR
External 
trigger
0
10
STMCR
TINT
1
st
 Byte
2
nd
 Byte
TDRE
Transmission 
data
Output transmission data when there is a 
match between STMR and STMCR
No data transmission because 
there is no data (TDRE=0)
3
rd
 Byte
L
TDR RW
TBI
4
th
 Byte
Output transmission data when there is a 
match between STMR and STMCR
TBYTE0
2
1
0
2
1
0
2
Transmissions 
counter*A
Load
Load
*A:Internal counter to be count transmission bytes
 
 
 
If the edge of the external trigger which is set with the trigger selection bit (SACSR:TRG1, 0) is detected 
during the transmission operation by the external trigger in progress under the following conditions, the 
transmission will not start. 
  When transmission is disabled (SCR:TXE="0") 
  When there is no valid data in the transmission data register (SSR:TDRE) 
 
 
 
 
MB91520 Series
MN705-00010-1v0-E
1477