Fujitsu FR81S User Manual

Page of 2342
CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
6. Operation of CSIO 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
187 
6.1.6. 
Timing of Timer Interrupt and Flag Setting 
Timer interrupt is generated when Serial Timer Register (STMR) matched Serial Timer Comparison 
Register (STMCR). 
  When Serial Timer Register (STMR) matched Serial Timer Comparison Register (STMCR), "1" will be 
set to timer interrupt flag (SACSR:TINT). 
At this time when the timer interrupt is enabled (SACSR:TINTE="1"), a status interrupt will be 
generated. 
 
Figure 6-5 Timer Interrupt Generation Timing 
10
0
1
2
・・・
9
10
1
0
STMR
STMCR
TINT
Timer activation
Generation of 
status interrupt
 
 
 
MB91520 Series
MN705-00010-1v0-E
1500