Fujitsu FR81S User Manual

Page of 2342
CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
8. Operation of I2C 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
350 
Figure 8-21 Master Transmission Interrupt (7)-when FIFO is Enabled   
(SSR:DMA="0", IBCR:WSEL="0", IBSR:RSA="0", ACK Response) 
 
 
             S    Slave Address  W   ACK     Data       ACK    Data       ACK  Data         ACK  P or Sr 
                                                                              △               △▲ 
                                                                              ①               ②  
S: Start condition 
W: Data direction bit (Write direction) 
P: Stop condition     
Sr: Repeated start condition 
: Interrupt because of INTE = "1" 
: Interrupt because of CNDE = "1" 
(1) An interrupt generated because the transmission FIFO is empty 
   - Write INT = "0" after the transmission data is written to the transmission FIFO 
(2) An interrupt generated by the last byte transmission (transmission FIFO is empty) +   
     acknowledgment reception 
   - Set MSS = "0" or MSS = "1" and SCC = "1" 
 
 
 
Figure 8-22 Master Transmission Interrupt (8)-when FIFO is Enabled 
(SSR:DMA="0", IBCR:WSEL="1", IBSR:RSA="0") 
 
 
             S    Slave Address  W   ACK     Data       ACK    Data       ACK  Data         ACK  P or Sr 
                                                                        △                △   ▲ 
                                                                        ①                ②  
S: Start condition 
W: Data direction bit (Write direction) 
P: Stop condition     
Sr: Repeated start condition 
: Interrupt because of INTE = "1" 
: Interrupt because of CNDE = "1" 
(1) An interrupt generated because the transmission FIFO is empty 
   - Write INT = "0" after the transmission data is written to the transmission FIFO 
(2) An interrupt generated by the last byte transmission (transmission FIFO is empty) 
   - Set MSS = "0" or MSS = "1" and SCC = "1" 
 
 
 
 
 
MB91520 Series
MN705-00010-1v0-E
1663