Fujitsu FR81S User Manual
CHAPTER 44: 12-BIT A/D CONVERTER
4. Registers
FUJITSU SEMICONDUCTOR LIMITED
CHAPTER
: 12-BIT A/D CONVERTER
FUJITSU SEMICONDUCTOR CONFIDENTIAL
56
4.2.15.
Activation Channel Conversion Completion Flag
Register : ADEOCF0, ADEOCF1
The bit configuration of the activation channel conversion completion flag register is shown.
The activation channel conversion completion flag register (ADEOCF) indicates the conversion count
completion of each activation channel when the conversion count specification scan is converted.
ADEOCF0: Address 145C
H
(Access: Byte, Half-word, Word)
bit31
bit30
bit29
bit28
bit27
bit26
bit25
bit24
EOCF31
EOCF30
EOCF29
EOCF28
EOCF27
EOCF26
EOCF25
EOCF24
Initial value
1
1
1
1
1
1
1
1
Attribute
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
EOCF23
EOCF22
EOCF21
EOCF20
EOCF19
EOCF18
EOCF17
EOCF16
Initial value
1
1
1
1
1
1
1
1
Attribute
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
bit15
bit14
bit13
bit12
bit11
bit10
bit9
bit8
EOCF15
EOCF14
EOCF13
EOCF12
EOCF11
EOCF10
EOCF9
EOCF8
Initial value
1
1
1
1
1
1
1
1
Attribute
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
EOCF7
EOCF6
EOCF5
EOCF4
EOCF3
EOCF2
EOCF1
EOCF0
Initial value
1
1
1
1
1
1
1
1
Attribute
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
R,WX
[bit31 to bit0] EOCF31 to EOCF0 : Conversion count completion flag bits
EOCF
Explanation
0
The count of the conversion count specification is not completed.
1
The count of the conversion count specification is completed.
The state of the data protection to the A/D data register of each activation channel is indicated.
MB91520 Series
MN705-00010-1v0-E
1859