Fujitsu FR81S User Manual

Page of 2342
CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
56 
4.2.15. 
Activation Channel Conversion Completion Flag 
Register : ADEOCF0, ADEOCF1 
The bit configuration of the activation channel conversion completion flag register is shown. 
The activation channel conversion completion flag register (ADEOCF) indicates the conversion count 
completion of each activation channel when the conversion count specification scan is converted.   
  ADEOCF0: Address 145C
H
 (Access: Byte, Half-word, Word) 
 
bit31 
bit30 
bit29 
bit28 
bit27 
bit26 
bit25 
bit24 
 
 
EOCF31 
EOCF30 
EOCF29 
EOCF28 
EOCF27 
EOCF26 
EOCF25 
EOCF24 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
 
 
 
 
 
 
 
 
 
bit23 
bit22 
bit21 
bit20 
bit19 
bit18 
bit17 
bit16 
 
 
EOCF23 
EOCF22 
EOCF21 
EOCF20 
EOCF19 
EOCF18 
EOCF17 
EOCF16 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
 
 
 
 
 
 
 
 
 
bit15 
bit14 
bit13 
bit12 
bit11 
bit10 
bit9 
bit8 
 
 
EOCF15 
EOCF14 
EOCF13 
EOCF12 
EOCF11 
EOCF10 
EOCF9 
EOCF8 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
 
 
 
 
 
 
 
 
 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
 
EOCF7 
EOCF6 
EOCF5 
EOCF4 
EOCF3 
EOCF2 
EOCF1 
EOCF0 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
[bit31 to bit0] EOCF31 to EOCF0 : Conversion count completion flag bits 
EOCF 
Explanation 
The count of the conversion count specification is not completed. 
The count of the conversion count specification is completed. 
 
The state of the data protection to the A/D data register of each activation channel is indicated. 
 
 
MB91520 Series
MN705-00010-1v0-E
1859