CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
69 
5.1.2. Scan conversion completion interrupt by conversion 
count specification 
The scan conversion completion interrupt by conversion count specification is explained. 
Table 5-2 Interrupt control bit and interrupt factor by scan conversion completion by 
conversion count specification 
 
Scan conversion completion interrupt by conversion 
count specification 
Interrupt request flag bit 
SCINT:bit7 of scan conversion control status register 
(ADSCANS) 
Interrupt request enable bit 
SCIE:bit6 of scan conversion control status register 
(ADSCANS) 
Interrupt factor 
After completing the A/D conversion of a specified count of the 
final activation channel in the scan conversion of the 
conversion count specification 
 
When the A/D conversion of a specified count of the final activation channel is completed, A/D activation 
compare can generate the interrupt request when the scan conversion by the conversion count specification 
is executed. Moreover, the scan conversion completion interrupt by the conversion count specification is 
controlled with each 12-bit A/D converter unit. 
When the A/D conversion of a specified count of the final activation channel of the scan conversion by the 
conversion count specification is completed, scan conversion completion interrupt factor flag bit 
(ADSCANS.SCINT) is set in "1". At this time, when the scan conversion completion interrupt request 
enable bit has been enabled (ADSCANS.SCIE="1"), the interrupt request is output to the interrupt 
controller. Moreover, the scan conversion by the conversion count specification is controlled by conversion 
count specification scan conversion execution enable bit (ADNCS.CNTEN) and conversion count 
specification bit (ADNCS.CCNT1, CCNT0). 
 