Fujitsu FR81S User Manual

Page of 2342
CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
87 
5.2.11. 
A/D conversion data 
The A/D conversion data is explained. 
The A/D conversion result data is stored in A/D data bit (ADTCD.D11 to D0) at each activation channel. 
Moreover, when the data protection function is disabled (ADTCS.PRT="0"), the state of the A/D conversion 
data stored in A/D data bit (ADTCD.D11 to D0) can be confirmed by the conversion data error flag bit 
(ADTCD.ERR) and the conversion data error status bit (ADTCD.ERRST). 
When the data protection function is enabled (ADTCS.PRT="1"), the conversion data error flag bit 
(ADTCD.ERR) and the conversion data error status bit (ADTCD.ERRST) are fixed to "0". 
Table 5-6 State confirmation of conversion data (When the data protection function is 
disabled) 
ADTCD.ERR 
ADTCD.ERRST 
State of A/D conversion data 
The latest data (read out not yet) 
- (It does not have the meaning) 
The old data (already read out)   
* initial value 
The latest data/ 
The over-writing is generated (read out not yet)   
* There is lost data 
 
MB91520 Series
MN705-00010-1v0-E
1890