CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
92 
Figure 5-16 Continuous scan conversion when conversion count of each channel is specified 
(In case of data protection function effective) 
stop
During 
conversion(N ch)
(The first)
During 
conversion(N+1 
ch)
(The first)
During 
conversion(N+2 
ch)
(The second)
During 
conversion(N+2 
ch)
(The first)
During 
conversion(N ch)
(The first)
Conversion frequency 
completion flag
(ADEOCF.ECOF
N
)
Invalid data
Conversion result(The 
first)
Conversion result(The second)
Invalid data
Conversion result(The first)
Invalid data
Conversion result(The 
second)
Conversion result(The first)
Software Activate 
request (n+1 channel)
A/D conversion
Activation trigger
Software Activate 
request (n channel)
Software Activate 
request (n+2 channel)
During 
conversion(N ch)
(The second)
Conversion frequency 
completion flag
(ADEOCF.ECOF
N+1
)
Conversion frequency 
completion flag
(ADEOCF.ECOF
N+2
)
Protection state flag
(ADPRT.PRTF
N
)
Protection state flag
(ADPRT.PRTF
N+1
)
Protection state flag
(ADPRT.PRTF
N+2
)
A/D data register
(ADTCD
N
.D11~D0)
A/D data register
(ADTCD
N+1
.D11~D0)
A/D data register
(ADTCD
N+2
.D11~D0)
Scanning conversion completion 
interruption factor flag
(ADSCANS.SCINT)
At continuous execution of a different start channel
The activate request of the next start channel is output regardless with the state 
of the data protection. 
When the final start channel processing to be 
scanned is completed, it is automatically an iterative 
implementation from the beginning as for the 
scanning conversion. 
stop
sto
p
stop
← Protection 
state release
← Protection 
state release
← Protection 
state release
← Protection 
state release
← Protection 
state release
The analog to digital conversion is restarted by the data 
protection state release at continuous execution in the same 
start channel. 
Software factor start (N, N+1 and 
N+2 channels simultaneous)
[Channel composition information]
  
Start channel N, N+1, and N+2: It are the repetition mode and the security function, and is a software start, a continuous 
scanning conversion mode, conversion frequency specification scanning conversion execution permission, and is a continuous 
conversion frequency: Start channel N+2 = twice start channel N+1 = once start channel N= twice
 
 
  Stop scan conversion when conversion count of each channel is specified 
The stop scan conversion when conversion count of each channel is specified is executed by the stop scan 
conversion mode is set (ADSCANS.SCMD="1"), the repeat conversion selection bit is set to repeat mode 
(ADTCS.RPT="1"), the conversion count specification scan conversion execution enable 
(ADNCS.CNTEN="1") is set, the conversion count specification (ADNCS.CCNT1,CCNT0="count") is set, 
and the A/D activation is set to the same activation factor at the same time on each activation channel of the 
scan conversion target. 
The stop scan conversion when conversion count of each channel is specified advances to the A/D 
conversion of the next activation channel when the A/D conversion of conversion count specification 
(ADNCS.CCNT1,CCNT0) is executed from activation channel (activation channel of the scan conversion 
target) small number, and conversion is completed. Moreover, the activation channel that completes the A/D 
conversion of the conversion count specification can be confirmed by conversion count completion flag bit 
(ADEOCF.EOCF). 
Then, when the A/D conversion of the conversion count specification of the final activation channel is 
completed, the scan conversion completion interrupt factor flag (ADSCANS.SCINT) is set in "1" and the 
scan conversion becomes the state of the stop. The scan conversion restarts (return from the state of the 
stop) when the A/D activation factor is generated even by one of the scan conversion targets. 
Moreover, the conversion count completion flag bit (ADEOCF.EOCF) of each activation channel is 
automatically cleared to "0" by restarting (return from the state of the stop) the scan conversion. 
The conversion count specification (ADNCS.CCNT1,CCNT0) can select 1 to 4 times of each activation 
channel. 
The data protection function can select invalidity and effective of each activation channel. Moreover, when 
the data protection function is effective (ADTCS.PRT="1"), the state of the data protection of each 
activation channel can be confirmed by data protection state flag bit (ADPRTF.PRTF). 
 
In case of data protection function invalid (ADTCS.PRT="0") 
The scan conversion continuously executes A/D conversions other than the state of the stop without 
stopping. The data of the A/D conversion data is not protected, and. the last A/D conversion data 
MB91520 Series
MN705-00010-1v0-E
1895