CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
93 
converted in the activation channel is stored. 
 
In case of data protection function effective (ADTCS.PRT="1") 
The data of the A/D conversion data is protected. Therefore, the A/D conversion in the same activation 
channel stops the A/D conversion for the data protection period. However, when the scan conversion 
shifts to a different activation channel, the A/D conversion is continuously executed without stopping 
because A/D data register (ADTCD) is also different. 
Notes: 
 
When the same activation factor as scan conversion target is set to the activation channel that is larger 
than the final channel of stop scan conversion, the activation channel that is larger than the final channel 
can execute the A/D conversion only for the stop period. 
 
The data protection function works at factors other than compare match activation 
(ADTECS.STS2="0", ADTCS.STS1,STS0="11
B
"). 
 
In the data protection function is effective (ADTCS.PRT="1"), please release the state of the data 
protection before starting the next scan conversion. The activation channel in the state of the data 
protection does not execute the A/D conversion. 
 
Figure 5-17 Stop scan conversion when conversion count of each channel is specified (In 
case of data protection function invalid) 
During 
conversion(N ch)
(The first)
During 
conversion(N+1 
ch)
(The first)
During 
conversion(N+2 
ch)
(The second)
During 
conversion(N+2 
ch)
(The first)
Conversion frequency 
completion flag
(ADEOCF.ECOF
N
)
Invalid data
Conversion 
result(The first)
Conversion result(The second)
Invalid data
Conversion result(The first)
Invalid data
Conversion result(The second)
Conversion 
result(The first)
Software Activate 
request (n+1 channel)
A/D conversion
Activation trigger
Software Activate 
request (n channel)
Software Activate 
request (n+2 channel)
During 
conversion(N ch)
(The second)
Conversion frequency 
completion flag
(ADEOCF.ECOF
N+1
)
Conversion frequency 
completion flag
(ADEOCF.ECOF
N+2
)
Protection state flag
(ADPRT.PRTF
N
)
Protection state flag
(ADPRT.PRTF
N+1
)
Protection state flag
(ADPRT.PRTF
N+2
)
A/D data register
(ADTCD
N
.D11~D0)
A/D data register
(ADTCD
N+1
.D11~D0)
A/D data register
(ADTCD
N+2
.D11~D0)
Scanning conversion completion 
interruption factor flag
(ADSCANS.SCINT)
When the final start channel processing to 
be scanned is completed, the scanning 
conversion is dormant. 
stop
Software factor start (N, 
N+1 and N+2 channels 
simultaneous)
Rest
← Factor clear
Software factor start 
(individual or plurals of N, 
N+1, and N+2)
The scanning conversion is restarted by 
the start demand generation. 
During 
conversion(N 
ch)
(The first)
When the analog to digital conversion of a specified frequency is 
completed, the activate request of the mask doing and the next start 
channel outputs the activate request. 
[Channel composition information]
  
Start channel N, N+1, and N+2: the repetition mode, the protection function none, the software start, the stop scanning conversion 
mode, the conversion frequency specification scanning conversion execution permission, and the continuous conversion frequency: Start 
channel N+2 = twice start channel N+1 = once start channel N= twice
 
MB91520 Series
MN705-00010-1v0-E
1896