Fujitsu FR81S User Manual

Page of 2342
CHAPTER 48: WAVEFORM GENERATOR 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : WAVEFORM GENERATOR 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
15 
[bit2 to bit0] TMD5 to TMD3 : Operation mode bits 
TMD5 
TMD4 
TMD3 
Function 
OUT signal will be output. 
If PPG output is disabled, OUT signal will be output. 
If PPG output is enabled, PPG pulse will be output while the 
OUT signal is "H". 
The rising edge of each OUT signal functions as a trigger and 
activates the 16-bit dead timer. 
If PPG output is disabled, "H" will be output until the 16-bit 
dead timer stops. 
If PPG output is enabled, PPG pulse will be output until the 
16-bit dead timer stops. 
(Timer mode) 
Non-overlap signal will be generated at OUT signal. 
(Dead time timer mode) 
Setting prohibited 
Others 
Setting prohibited 
 
These bits are used to select the operation mode for the waveform generator.   
 
If the TMD5 to TMD3: bit18 to bit16 are "000
B
", the compare output 2 and 3 signals of the output 
compare will be output from RTO2 and RTO3 respectively. The 16-bit dead timer can also be used as a 
reload timer.   
 
If the TMD5 to TMD3: bit18 to bit16 are "001
B
", the compare output 2 and 3 signals of the output 
compare will be output from RTO2 and RTO3 respectively when PPG output is disabled 
(PGEN2:bit28=0, PGEN3:bit29=0 of the PPG output control register (PICS0)). When PPG output is 
enabled (PGEN2:bit28=1, PGEN3:bit29=1 of PPG output control register (PICS0)), PPG pulse will be 
output from RTO2 and RTO3 respectively while the compare output 2 and 3 signals of the output 
compare are "H". The 16-bit dead timer can also be used as a reload timer.   
 
The rising edge of each OUT signal functions as a trigger and activates the 16-bit dead timer when 
TMD5 to TMD3: bit18 to bit16 are "010
B
". If PPG output is disabled, "H" will be output until the 16-bit 
dead timer stops. If PPG output is enabled, PPG pulse will be output until the 16-bit dead timer stops. 
(Timer mode) 
 
When TMD5 to TMD3: bit18 to bit16 are "100
B
", non-overlap signal will be generated at the OUT 
signal. (Dead time timer mode) 
 
Note: 
To operate the waveform generator in the dead time timer mode, be sure to select the 2-channel mode 
(compare control register (OCS23); CMOD: bit28=1) for the compare output 3 of the output compare. 
 
 
MB91520 Series
MN705-00010-1v0-E
2060