Fujitsu FR81S User Manual

Page of 2342
CHAPTER 48: WAVEFORM GENERATOR 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : WAVEFORM GENERATOR 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
30 
5.2.  Operation of the Waveform Generator 
The operation of the waveform generator is explained. 
The waveform generator can generate various types of waveforms (including dead time) using the real-time 
output (RTO0 to RTO5), 16-bit PPG timer 0/2/4, and 16-bit dead timer 0/1/2. 
Output state of RTO0 to RTO5 and GATE 
 
Table 5-4 RTO/GATE Output State and Bit Settings 
TMD2  TMD1  TMD0  GTEN  PGEN 
RTO 
GATE 
Compare output OUT 
(16-bit output compare output) 
Always "0" 
0/1 
Compare output OUT 
(16-bit output compare output) 
(OUT and GTEN) 
*3
 
Output the PPG0/PPG2/PPG4 
pulses while the OUT is "H" 
*1
 
Always "0" 
Output the PPG0/PPG2/PPG4 
pulses activated by GATE signals 
while the OUT is "H" 
OUT 
0/1 
Activate the 16-bit dead timer by the 
rising edge of OUT, and "H" is being 
output until the 16-bit dead timer 
underflows. 
When GTEN and 
the timer is active, 
"H" is being 
output
*4
 
Activate the 16-bit dead timer by the 
rising edge of OUT, and 
PPG0/PPG2/PPG4 pulses are being 
output until the 16-bit dead timer 
underflows.
*1
 
Always "0" 
Activate the 16-bit dead timer by the 
rising edge of OUT, and 
PPG0/PPG2/PPG4 pulses activated 
by GATE signals are being output 
until the 16-bit dead timer 
underflows. 
When the timer 
is active, "H" 
is being output
*4
 
Generate a non-overlap signal at 
OUT 
*2
 
Always "0" 
Setting prohibited 
Setting prohibited 
Others 
Always "0" 
Always "0" 
*1: You will need to select a channel you wish to use from the PPG0/PPG2/PPG4 and activate the PPG in 
advance. 
*2: To generate a non-overlap signal, make sure to select the 2-channel mode (compare control register 
(OCS1, OCS3, OCS5); CMOD=1) for the OUT1, OUT3, and OUT5. 
*3: GATE signal will be generated from the OUT of which GTEN bit is set to "1". 
*4: GATE signal will be generated during the operation of the timer activated by the OUT of which GTEN bit 
is set to "1". If more than one GATE bit is set to "1", GATE signal will be the OR signal of signals in each 
active timer operation. 
 
MB91520 Series
MN705-00010-1v0-E