1.  Overview 
This section explains the overview of the Timing Protection Unit. 
Timing Protection Unit (TPU) is a timer that OS uses for the ensuring safety of the system by the watch of 
the time of Task/ISR. The control target that OS supervises is as follows. 
  Resource lock time 
  Global interrupt lock time 
  Task/ISR dead line 
  Task/ISR runtime 
  Inter-arrival time ( Interrupt Frequency ) 
 
The control registers can be accessed only in a privileged mode because the built-in timers of TPU are 
controlled by OS, and the controls are all programmable. 
 