5.2.  Global Prescaler 
The section explains the global prescaler. 
The global prescaler is a common prescaler used with all timers of TPU. The global prescaler divides 
HCLK (input clock of TPU) according to a set value of TPUCFG.GLBPS[5:0]. The value of division can be 
set by 1 to 64. 
The global prescaler function controls operation by the TPUCFG.GLBPSE bit.    The global prescaler 
function is enabled by writing one in TPUCFG.GLBPSE and it is disabled by writing 0 in 
TPUCFG.GLBPSE. 
When TPUCFG.GLBPSE=0, the prescaler function is disabled and the clock of all timers doesn't become 
valid. 
Please, update TPUCFG.GLBPS[5:0] after setting disable the global prescaler function 
(TPUCFG.GLBPE=0). 