Fujitsu FR81S User Manual

Page of 2342
CHAPTER 5: CLOCK 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : CLOCK 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
79 
5.6.1.   Procedure of Gear Up 
The procedure of gear up is shown. 
1.  The clock of the start step set to the clock gear start step selection is output after the oscillation 
stabilization wait timer completes. 
2.  When the clock gear start (CCCGRCR0:GRSTR) is set to "1" and the rising is detected, the clock gear 
status flag (CCCGRCR0:GRSTS[1:0]) transits to "00" → "01" (gear up start). 
3.  The gear up is executed according to the clock gear step selection and the repeat number selection. The 
step number is the smaller and the repeat number is the larger that the operation changes the more 
gradually 
4.  When the clock reaches the maximum step, the clock gear status flag (CCCGRCR0:GRSTS[1:0]) 
transits to "01" → "10" 
(the end of gear up, the gear stops). After this, a clock is output at the maximum step (64 steps). 
5.  After the gear stops, the clock gear start (CCCGRCR0:GRSTR) is cleared to "0" by hardware. 
 
MB91520 Series
MN705-00010-1v0-E
240