Fujitsu FR81S User Manual

Page of 2342
CHAPTER 17: PPG 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : PPG 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
49 
5.6.  GATE Operation 
The GATE operation is explained. 
PPG can be activated/stopped by GATE signals from the waveform generator. PPG activation valid time 
can be controlled by the EDGE bit of the GATE control register (GATEC:EDGE) and GATE signals from 
the waveform generator. 
Figure 5-7 PPG Count Operation by GATE Function 
GATE signal
PPG
Down counter
PPG output
(OSEL=0)
EDGE=0(rising activation → falling stop)
GATE signal
PPG
downcounter
PPG output
(OSEL=0)
EDGE=1(falling activation → rising stop)
Start
Stop
Start
Start
Stop
Start
PCN:MDSE=0(PWM operation)
PCN:MDSE=0(PWM operation)
 
If the one-shot pulse operation (PCN:MDSE= "1") is set when PPG operation is selected (GATEC:STGR) 
by GATE function, continuous pulses are output from the PPG output pin in the same way as the PWM 
operation. 
 
GATE signals from 
the waveform 
generator 
GATE signals from 
the waveform 
generator 
MB91520 Series
MN705-00010-1v0-E
590