Fujitsu FR81S User Manual

Page of 2342
CHAPTER 17: PPG 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : PPG 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
64 
5.14.  Interrupt 
The interrupt is explained. 
The interrupt request is generated for the following either. 
  Software trigger, External trigger, and GATE signal trigger 
  Counter borrow occurrence (The set cycle is matched) 
  Match of duty 
  Match of Timing Point Capture value 
  PPG communication data register Empty flag 
 
The generated interrupt factor is different depending on the operation mode of PPG. 
Table 5-1 Correspondence of Operation Mode and Interrupt Request 
Interrupt request 
PWM operation and 
one-shot operation 
Timing Point 
Capture mode 
PPG 
communication 
mode 
Software trigger, External 
trigger, and GATE signal 
trigger 
 
 
 
Counter borrow occurrence 
 
 
 
Match of counter and duty 
value 
 
 
 
Counter borrow occurrence, 
or match of counter and duty 
value 
 
 
 
Match of Timing Point 
Capture value 
 
 
 
PPG communication data 
register Empty factor 
 
 
 
 
Table 5-2 shows the register related to the interrupt of each operation mode. 
Table 5-2 Interrupt Setting of Each Operation Mode 
Interrupt setting 
Setting of 
interrupt factor    Interrupt flag 
Interrupt 
request enable 
Clear of 
interrupt 
request 
PWM operation, 
One shot operation 
PCNn.IRS[1:0] 
=00 to 11 
PCNn.IRQF=1 
PCNn.IREN=1 
"0" is written in 
PCN.IRQF. 
Timing point capture 
mode 
PCN2n.IRS[2:0] 
=000 to 100 
PCNn.IRQF=1 
PCNn.IREN=1 
"0" is written in 
PCN.IRQF. 
PPG communication 
mode 
PCN2n.IRS[2:0] 
=101 to 111 
PCN2n.REMP=1 
or 
PSC2n.SREMP=1 
PCNn.IREN=1 
"0" is written in 
PCN.IRQF. 
(n=0 to 47) 
PCN: PPG control register 
PCN2: PPG control register2 
MB91520 Series
MN705-00010-1v0-E
605