CHAPTER 21: 32-BIT FREE-RUN TIMER 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 32-BIT FREE-RUN TIMER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
23 
[bit17, bit16] IS81, IS80 : free-run timer selector for input capture 8 
IS81 
IS80 
Function 
Free-run timer 3 
Free-run timer 4 
Free-run timer 5 
Setting prohibit (operation is not guaranteed) 
These bits are used to configure the free-run timer assigned to the input capture 8. 
Note: 
Before configuring these bits, make sure to verify that the free-run timer is inactive. 
 
[bit15, bit14] : Undefined 
The read value is "0". Writing has no effect on operation. 
[bit13, bit12] IS71, IS70 : free-run timer selector for input capture 7 
IS71 
IS70 
Function 
Free-run timer 3 
Free-run timer 4 
Free-run timer 5 
Setting prohibit (operation is not guaranteed) 
These bits are used to configure the free-run timer assigned to the input capture 7. 
Note: 
Before configuring these bits, make sure to verify that the free-run timer is inactive. 
 
[bit11, bit10] : Undefined 
The read value is "0". Writing has no effect on operation. 
[bit9, bit8] IS61, IS60 : free-run timer selector for input capture 6 
IS61 
IS60 
Function 
Free-run timer 3 
Free-run timer 4 
Free-run timer 5 
Setting prohibit (operation is not guaranteed) 
These bits are used to configure the free-run timer assigned to the input capture 6. 
Note: 
Before configuring these bits, make sure to verify that the free-run timer is inactive. 
 
MB91520 Series